General Information

Torque Specifications for metric fasteners (PDF, 130Kb)

HMF-02
HMF-02 installation and start-up instructions (PDF, 311,3Kb)
Adjusting the single-setting relief valves (PDF, 264,3Kb)
Adjusting the dual-stage relief valves with internal shimming (PDF, 798,9Kb)
Adjusting the dual-stage relief valves with all external adjustments (PDF, 544,Kb)
HMF-02 Swing Priority Motor: Adjusting the flow stops (PDF, 304,7Kb)
HMF-02 Swing Priority Motor: Adjusting the regulation begin pressure (PDF, 411,9Kb)
HMF-02 Swing Priority Motor: Adjusting the maximum torque setting (PDF, 323,Kb)
HMF-02 Swing Priority Motor: Adjusting the position of the torque curve (PDF, 321,4Kb)

HMV-02
HMV-02 installation and start-up instructions (PDF, 322,2Kb)
Adjusting the minimum displacement (PDF, 325,Kb)
Adjusting the maximum displacement (PDF, 325,2Kb)
Adjusting the hydraulic infinitely variable control (PDF, 428,9Kb)
Adjusting the electric infinitely variable control (PDF, 331,3Kb)
Adjusting the pressure compensator (PDF, 266,6Kb)

HMV-02 Double Motor
Adjusting the hydraulic neutral (PDF, 310,2Kb)
Adjusting the electric regulation begin (PDF, 431,Kb)
Adjusting the minimum displacement (PDF, 345,Kb)
Adjusting the maximum displacement (PDF, 299,8Kb)

HMR-02
HMR-02 installation and start-up instructions (PDF, 320,4Kb)
Adjusting the minimum displacement (PDF, 280,9Kb)
Adjusting the maximum displacement (PDF, 301,2Kb)
Adjusting the regulation begin pressure (PDF, 298,6Kb)
Adjusting the cross-over relief valves (PDF, 388,7Kb)

HPR-02
HPR-02 installation and start-up instructions (PDF, 357,7Kb)
Adjusting the minimum displacement (PDF, 283,5Kb)
Adjusting the maximum displacement (PDF, 286,3Kb)
Checking the stand-by pressure (PDF, 219,7Kb)
Adjusting the pressure compensation pump control: Adjusting the load sense margin      pressure and the pressure compensator (PDF, 327,4Kb)
Adjusting the VD3 pump control: Adjusting the load sense margin pressure and the VD3      performance valve (PDF, 370,0Kb)

HPV-02
HPV-02 installation and start-up instructions (PDF, 567,2Kb)
Adjusting the hydraulic neutral for cam control (M1) (PDF, 243,1Kb)
Adjusting the hydraulic neutral for all other HPV-02 controls (PDF, 326,7Kb)
Adjusting the regulation begin pressure: For hydraulic control (PDF, 374,5Kb)
Adjusting the regulation begin pressure: For electro-hydraulic control (PDF, 240,1Kb)
Adjusting the regulation begin pressure: For hydraulic-cam control (M2) (PDF, 378,8Kb)
Adjusting the maximum displacement: For hydraulic and electro-hydraulic controls 
     (PDF, 302,5Kb)

Adjusting the maximum displacement: For hydraulic-cam control (PDF, 243,7Kb)
Adjusting the maximum displacement: For cam control (PDF, 234,7Kb)
Adjusting the deadband on hydraulic-cam controls (PDF, 195,8Kb)
Adjusting the pressure override: For hydraulic control with CW rotation (PDF, 434,0Kb)
Adjusting the pressure override: For hydraulic control with CCW rotation (PDF, 431,7Kb)
Adjusting the pressure override: For Electro-hydraulic control with CW rotation
    
(PDF, 436,3Kb)
Adjusting the pressure override: For Electro-hydraulic control with CCW rotation
      (PDF, 438,Kb)

Adjusting the pressure override: For hydraulic-cam control with CW rotation
     (PDF, 432,6Kb)

Adjusting the pressure override: For hydraulic-cam control with CCW rotation
     (PDF, 438,4Kb)

Changing the HPV-02 response orifices (PDF, 324,1Kb)
New Unidirectional Charge Pump (PDF, 286,3Kb)

LSC Valve Adjustments
Guidelines to start-up an LSC system (PDF, 283,7Kb)
Adjusting valve flow stops: When the desired flow is UNKNOWN (PDF, 250,Kb)
Adjusting valve flow stops: When the desired flow is KNOWN (PDF, 334,7Kb)
Adjusting workport relief valves (PDF, 248,2Kb)
Adjusting regulation begin (PDF, 372,4Kb)
Adjusting 2-stage load sense PCO (PDF, 367,0Kb)
Adjusting 1-stage load sense PCO (PDF, 365,1Kb)
Adjusting PCO and system relief valve on monoblocks (PDF, 435,2Kb)
Checking plug positions on monoblock for PCO, system relief, and safety relief valve
     configurations (PDF, 300,7Kb)

HPR-01
Measuring stand-by pressure (PDF, 152,9Kb)
Adjusting maximum displacement for single pump with LS/VD3 control (PDF, 294,8Kb)
Adjusting minimum displacement for single pump with LS/VD3 control (PDF, 291,7Kb)
Adjusting LS/VD3 pump control (PDF, 309,3Kb)
Adjusting load sense margin pressure on single pump with LS/horsepower control
     (PDF, 162,3Kb)

Adjusting load sense margin pressure for double with LS/horsepower control
     (PDF, 410,2Kb)

Adjusting horsepower for double pump with LS/horsepower control (PDF, 284,6Kb)
Adjusting pressure compensation control for single pump with LS/pressure compensation
     control (PDF, 619,2Kb)

BPV-01
Adjusting the pressure override: For hydraulic control with CW rotation (PDF, 680,5Kb)
Adjusting the pressure override: For hydraulic control with CCW rotation (PDF, 674,Kb)
Adjusting the pressure override: For electro-hydraulic control with CW rotation
     (PDF, 723,8Kb)

Adjusting the pressure override: For electro-hydraulic control with CCW rotation
     (PDF, 726,8Kb)

BMR-01
Adjusting regulation begin on BMR186 (PDF, 301,2Kb)

BMF/V/R-01
Information on Bearing Changes BMF/V/R-01 Series Motors (PDF, 43,1Kb)

 